The contact gasket stress distributions in a rectangular box-shape bolted flange connection with a compressed sheet gasket subjected to internal pressure were analyzed using the finite element method. Leakage tests were also conducted for an actual rectangular box-shape bolted flange connection with a compressed sheet gasket under internal pressure. Using the obtained contact gasket stress distributions and the results of the leakage tests, the new gasket constants were calculated. The difference in the new gasket constants between the values obtained from the present study and those from the Pressure Vessel Research Council (PVRC) procedure was substantial. In addition, a method to determine the bolt preload for a given tightness parameter was demonstrated and the difference in the determined bolt preload was shown between the present study and the PVRC procedure. The characteristics of the rectangular box-shape bolted flange connection were demonstrated by comparing those of circular bolted flange connections.
Skip Nav Destination
e-mail: sawa@mec.hiroshima-u.ac.jp
e-mail: ryou.kurosawa@jp.yokogawa.com
Article navigation
April 2011
Research Papers
Stress Analysis and Sealing Performance Evaluation in Rectangular Box-Shape Bolted Flange Connection With Gasket Subjected to Internal Pressure
Toshiyuki Sawa,
Toshiyuki Sawa
Graduate School of Engineering,
e-mail: sawa@mec.hiroshima-u.ac.jp
Hiroshima University
, 1-4-1 Kagamiyama, Higashi-Hiroshima-shi, Hiroshima, 739-8527, Japan
Search for other works by this author on:
Ryo Kurosawa,
e-mail: ryou.kurosawa@jp.yokogawa.com
Ryo Kurosawa
Yokogawa Electric Corporation
, 9-32, Nakacho 2-chrome, Musashino-shi, Tokyo 180-8750,Japan
Search for other works by this author on:
Wataru Maezaki
Wataru Maezaki
University of Yamanashi
, 4-4-37, Takeda, Kofu, Yamanashi, 400-8510 Japan
Search for other works by this author on:
Toshiyuki Sawa
Graduate School of Engineering,
Hiroshima University
, 1-4-1 Kagamiyama, Higashi-Hiroshima-shi, Hiroshima, 739-8527, Japane-mail: sawa@mec.hiroshima-u.ac.jp
Ryo Kurosawa
Yokogawa Electric Corporation
, 9-32, Nakacho 2-chrome, Musashino-shi, Tokyo 180-8750,Japane-mail: ryou.kurosawa@jp.yokogawa.com
Wataru Maezaki
University of Yamanashi
, 4-4-37, Takeda, Kofu, Yamanashi, 400-8510 JapanJ. Pressure Vessel Technol. Apr 2011, 133(2): 021201 (8 pages)
Published Online: January 31, 2011
Article history
Received:
January 31, 2007
Revised:
March 30, 2010
Online:
January 31, 2011
Published:
January 31, 2011
Citation
Sawa, T., Kurosawa, R., and Maezaki, W. (January 31, 2011). "Stress Analysis and Sealing Performance Evaluation in Rectangular Box-Shape Bolted Flange Connection With Gasket Subjected to Internal Pressure." ASME. J. Pressure Vessel Technol. April 2011; 133(2): 021201. https://doi.org/10.1115/1.4001651
Download citation file:
Get Email Alerts
Cited By
Influence of water cover on the blast resistance of circular plates
J. Pressure Vessel Technol
Dynamic response and damage analysis of a large steel tank impacted by an explosive fragment
J. Pressure Vessel Technol
Surface Strain Measurement for Non-Intrusive Internal Pressure Evaluation of A Cannon
J. Pressure Vessel Technol
Related Articles
New Development in Studies on the Characteristics of Bolted Pipe Flange Connections in JPVRC
J. Pressure Vessel Technol (February,2006)
On the Effect of External Bending Loads in Bolted Flange Joints
J. Pressure Vessel Technol (April,2009)
Effect of Bolt Spacing on the Circumferential Distribution of the Gasket Contact Stress in Bolted Flange Joints
J. Pressure Vessel Technol (August,2011)
Related Proceedings Papers
Related Chapters
Standardization of Valves, Flanges, Fittings and Gaskets (ASME B16 Standard)
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Openings
Guidebook for the Design of ASME Section VIII Pressure Vessels
Section VIII: Division 2–Alternative Rules
Companion Guide to the ASME Boiler & Pressure Vessel Codes, Volume 2, Sixth Edition