Skip Nav Destination
Issues
June 2019
ISSN 1932-6181
EISSN 1932-619X
In this Issue
Review Article
Value-Based Care: A Review of Key Challenges and Opportunities Relevant to Medical Technology Innovators
J. Med. Devices. June 2019, 13(2): 020801.
doi: https://doi.org/10.1115/1.4042794
Topics:
Biomedicine
,
Health care
,
Performance
Research Papers
Dynamic Compression Garments for Sensory Processing Disorder Treatment Using Integrated Active Materials
J. Med. Devices. June 2019, 13(2): 021001.
doi: https://doi.org/10.1115/1.4042599
Topics:
Actuators
,
Compression
,
Pressure
,
Shape memory alloys
,
Active materials
,
Springs
,
Design
,
Patient treatment
Programmable Multistable Mechanisms for Safe Surgical Puncturing
Mohamed Zanaty, Thomas Fussinger, Arno Rogg, Andrea Lovera, David Lambelet, Ilan Vardi, Thomas J. Wolfensberger, Charles Baur, Simon Henein
J. Med. Devices. June 2019, 13(2): 021002.
doi: https://doi.org/10.1115/1.4043016
Topics:
Computer programming
,
Design
,
Displacement
,
Drugs
,
Needles
,
Surgery
,
Stability
,
Dimensions
,
Lasers
,
Glass
The Role of Tissue Slip Feedback in Robot-Assisted Surgery
J. Med. Devices. June 2019, 13(2): 021003.
doi: https://doi.org/10.1115/1.4043018
Topics:
Biological tissues
,
Feedback
,
Surgery
,
Sensors
Portable Device for Measuring Blood Test Hemolyzed Samples Based on Computer Vision and Neural Network
Karyn Martinelli Lopes, Flavia Helena da Silva, Alessandra S. Gil Maldonado, Simone Aparecida Santiago, Tavani A. Pires, Claudia Maria Ferrer, Sara Josa Mena, Maria Emilia Germani Moura, Pietro Teruya Domingues, Lincoln Makoto Kawakami, Eduardo de Senzi Zancul
J. Med. Devices. June 2019, 13(2): 021004.
doi: https://doi.org/10.1115/1.4043078
Topics:
Artificial neural networks
,
Blood
,
Computers
,
Errors
,
Design
,
Image processing
,
Plasmas (Ionized gases)
,
User interfaces
Compact Two Degrees-of-Freedom External Fixator System for Correction of Persistent Clubfoot Deformity
J. Med. Devices. June 2019, 13(2): 021005.
doi: https://doi.org/10.1115/1.4043109
Topics:
Degrees of freedom
,
Surgery
,
Trajectories (Physics)
,
Optimization
Design and Modeling of a Three-Degree-of-Freedom Articulating Robotic Microsurgical Forceps for Trans-Oral Laser Microsurgery
J. Med. Devices. June 2019, 13(2): 021006.
doi: https://doi.org/10.1115/1.4043017
Topics:
Design
,
Lasers
,
Robotics
,
Rotation
,
Surgery
,
Manipulators
,
Instrumentation
An Electronic Force Sensor for Medical Jet Injection
J. Med. Devices. June 2019, 13(2): 021007.
doi: https://doi.org/10.1115/1.4043196
Topics:
Biological tissues
,
Biomedicine
,
Calibration
,
Ejectors
,
Errors
,
Force sensors
,
Nozzles
,
Sensors
,
Design
,
Needles
Measurement of Frictional Properties of Aortic Stent Grafts and Their Delivery Systems
Tianhao Chen, Michael Lancaster, Dawn S. Y. Lin, Matthew G. Doyle, Thomas L. Forbes, Cristina H. Amon
J. Med. Devices. June 2019, 13(2): 021008.
doi: https://doi.org/10.1115/1.4043292
A Proof-of-Concept Demonstration for a Novel Soft Ventricular Assist Device
Saleh H. Gharaie, Amir Ali Amir Moghadam, Subhi J. Al'Aref, Alexandre Caprio, Seyedhamidreza Alaie, Mohamed Zgaren, James K. Min, Simon Dunham, Bobak Mosadegh
J. Med. Devices. June 2019, 13(2): 021009.
doi: https://doi.org/10.1115/1.4043052
Topics:
Blood
,
Flow (Dynamics)
,
Pressure
,
Ventricular assist devices
,
Design
,
Heart failure
,
Valves
,
Pulsatile flow
,
Echocardiography
,
Pumps
Water Jet Applicator for Interface Tissue Removal in Minimally Invasive Hip Refixation: Testing the Principle and Design of Prototype
J. Med. Devices. June 2019, 13(2): 021010.
doi: https://doi.org/10.1115/1.4043293
Topics:
Biological tissues
,
Design
,
Ducts
,
Engineering prototypes
,
Jets
,
Suction
,
Water
,
Testing
,
Dimensions
,
Water supply
Pulse Oximeter for Low SpO2 Level Detection Using Discrete Time Signal Processing Algorithm
Sumit Pandey, Cher Ming Tan, Hsiao-Wen Chen, Yao En Xie, Jung Hua Tung, Yu-Chuan Kau, Chia-Chih Liao
J. Med. Devices. June 2019, 13(2): 021011.
doi: https://doi.org/10.1115/1.4043588
Topics:
Algorithms
,
Blood
,
Noise (Sound)
,
Oxygen
,
Signal processing
,
Signals
,
Hardware
,
Errors
,
Design
,
Probes
Technology Review
A Systematic Review of Noninvasive Electrocardiogram Monitoring Devices for the Evaluation of Suspected Cardiovascular Syncope
Monica Solbiati, Lucia Trombetta, Roberto M. Sacco, Luca Erba, Viviana Bozzano, Giorgio Costantino, Satish R. Raj, Franca Barbic, Giovanni Casazza, Franca Dipaola, Raffaello Furlan, Rose A. Kenny, James V. Quinn, Robert S. Sheldon, Win-Kuang Shen, Benjamin C. Sun, Venkatesh Thiruganasambandamoorthy, Matthew J. Reed
J. Med. Devices. June 2019, 13(2): 024001.
doi: https://doi.org/10.1115/1.4042795
Topics:
Cardiovascular system
,
Telemetry
,
Diseases
,
Internet
Technical Brief
Percutaneous Ultrasound Gastrostomy: A Novel Device and Bedside Procedure for Gastrostomy Tube Insertion Using Magnetic and Ultrasound Guidance
R. Gentry Wilkerson, Aliaksei Pustavoitau, Howard Carolan, Nolan Benner, Clark Fischer, Daniel J. Sheets, Peggy I. Wang, Steven Tropello
J. Med. Devices. June 2019, 13(2): 024501.
doi: https://doi.org/10.1115/1.4042866
Topics:
Biomedicine
,
Magnets
,
Safety
,
Testing
,
Ultrasound
,
Biological tissues
,
Skin
,
Visualization
,
Design
,
Errors