An experimental investigation on air natural convection, in a vertical channel asymmetrically heated at uniform heat flux, with downstream unheated parallel extensions, is carried out. One extension is coplanar to the unheated channel wall and the distance between the extensions is equal to or greater than the channel gap (geometrically asymmetric chimney). Experiments are performed with different values of the wall heat flux, aspect ratio (Lhb), extension ratio (LLh) and expansion ratio (Bb). For the largest value of the aspect ratio (Lhb=10), the adiabatic extensions improve the thermal performance in terms of lower maximum wall temperature of the channel. Optimal configurations of the system with asymmetrical chimney are detected. Flow visualization shows a cold inflow in the channel-chimney system that penetrates down below the channel exit section. Maximum wall temperatures and channel Nusselt numbers are correlated to the channel Rayleigh number, Ra*, and to the geometrical parameters, in the ranges 3.0×102Ra*Bb1.0105, 1.0Bb3.0 and 1.0LLh4.0 with Lhb=5.0 and 10.0.

1.
Kim
,
S. J.
, and
Lee
,
S. W.
, 1996,
Air Cooling Technology for Electronic Equipment
,
CRC Press
, Boca Raton, FL.
2.
Manca
,
O.
,
Morrone
,
B.
,
Nardini
,
S.
, and
Naso
,
V.
, 2000, “
Natural Convection in Open Channels
,” in
Computational Analysis of Convection Heat Transfer
,
WIT Press
, Southampton, pp.
235
278
.
3.
Bianco
,
N.
,
Morrone
,
B.
,
Nardini
,
S.
, and
Naso
,
V.
, 2000, “
Air Natural Convection between Inclined Parallel Plates with Uniform Heat Flux at the Walls
,”
Int. J. Heat Technol.
,
18
(
2
), pp.
27
36
.
4.
Haaland
,
S. E.
, and
Sparrow
,
E. M.
, 1983, “
Solutions for the Channel Plume and the Parallel-Walled Chimney
,”
Numer. Heat Transfer
0149-5720,
6
, pp.
155
172
.
5.
Oosthuizen
,
P. H.
, 1984, “
A Numerical Study of Laminar Free Convective Flow through a Vertical Open Partially Heated Plane Duct
,”
ASME HTD
,
32
, pp.
41
48
.
6.
Asako
,
Y.
,
Nakamura
,
H.
, and
Faghri
,
M.
, 1990, “
Natural Convection in a Vertical Heated Tube Attached to Thermally Insulated Chimney of a Different Diameter
,”
ASME J. Heat Transfer
0022-1481,
112
, pp.
790
793
.
7.
Straatman
,
A. G.
,
Tarasuk
,
J. D.
, and
Floryan
,
J. M.
, 1993, “
Heat Transfer Enhancement from a Vertical, Isothermal Channel Generated by the Chimney Effect
,”
ASME J. Heat Transfer
0022-1481,
115
, pp.
395
402
.
8.
Lee
,
K. T.
, 1994, “
Natural Convection in Vertical Parallel Plates with an Unheated Entry or Unheated Exit
,”
Numer. Heat Transfer, Part A
1040-7782,
25
, pp.
477
493
.
9.
Fisher
,
T. S.
,
Torrance
,
K. E.
, and
Sikka
,
K. K.
, 1997, “
Analysis and Optimization of a Natural Draft Heat Sink System
,”
IEEE Trans. Compon., Packag. Manuf. Technol., Part A
1070-9886,
20
, pp.
111
119
.
10.
Fisher
,
T. S.
, and
Torrance
,
K. E.
, 1998, “
Free Convection Limits for Pin-Fin Cooling
,”
ASME J. Heat Transfer
0022-1481,
120
, pp.
633
640
.
11.
Campo.
,
A.
,
Manca
,
O.
, and
Morrone
,
B.
, 1999, “
Numerical Analysis of Partially Heated Vertical Parallel Plates in Natural Convective Cooling
,”
Numer. Heat Transfer, Part A
1040-7782,
36
, pp.
129
151
.
12.
Shahin
,
G. A.
, and
Floryan
,
J. M.
, 1999, “
Heat Transfer Enhancement Generated by the Chimney Effect in Systems of Vertical Channel
,”
ASME J. Heat Transfer
0022-1481,
121
, pp.
230
232
.
13.
Fisher
,
T. S.
, and
Torrance
,
K. E.
, 1999, “
Experiments on Chimney-Enhanced Free Convection
,”
ASME J. Heat Transfer
0022-1481,
121
, pp.
607
608
.
14.
Trasher
,
W. W.
,
Fisher
,
T. S.
, and
Torrance
,
K. E.
, 2000, “
Experiments on Chimney-Enhanced Free Convection from Pin-Fin Heat Sinks
,”
ASME J. Heat Transfer
0022-1481,
122
, pp.
350
357
.
15.
Auletta
,
A.
,
Manca
,
O.
,
Morrone
,
B.
, and
Naso
,
V.
, 2001, “
Heat Transfer Enhancement by the Chimney Effect in a Vertical Isoflux Channel
,”
Int. J. Heat Mass Transfer
0017-9310,
44
, pp.
4345
4357
.
16.
Manca
,
O.
,
Musto
,
M.
, and
Naso
,
V.
,
2001
, “
Experimental Analysis of Chimney Effect in a Vertical Isoflux Channel
,”
Proceedings of 5th World Conference on Experimental Heat Transfer, Fluid Dynamics and Thermodynamics
, Thessaloniki, Greece.
17.
Auletta
,
A.
, and
Manca
,
O.
, 2002, “
Heat and Fluid Flow Resulting from the Chimney Effect in a Symmetrically Heated Vertical Channel with Adiabatic Extensions
,”
Int. J. Therm. Sci.
1290-0729,
41
, pp.
1101
1111
.
18.
Manca
,
O.
,
Musto
,
M.
, and
Naso
,
V.
, 2003, “
Experimental Analysis of Asymmetrical Isoflux Channel-Chimney Systems
,”
Int. J. Therm. Sci.
1290-0729,
42
, pp.
837
846
.
19.
Aung
,
W.
,
Fletcher
,
L. S.
, and
Sernas
,
V.
, 1972, “
Developing Laminar Free Convection between Vertical Flat Plates with Asymmetric Heating
,”
Int. J. Heat Mass Transfer
0017-9310,
15
, pp.
2293
2308
.
20.
Webb
,
B. W.
, and
Hill
,
D. P.
, 1989, “
High Rayleigh Number Laminar Natural Convection in an Asymmetrical Heated Vertical Channel
,”
ASME J. Heat Transfer
0022-1481,
111
, pp.
649
656
.
21.
Kline
,
S. J.
, and
McClintock
,
F. A
, 1953, “
Describing Uncertainty in Single Sample Experiments
,”
Mech. Eng. (Am. Soc. Mech. Eng.)
0025-6501,
75
, pp.
3
12
.
22.
Moffat
,
R. J.
, 1988, “
Describing the Uncertainties in Experimental Results
,”
Exp. Therm. Fluid Sci.
0894-1777,
1
, pp.
3
17
.
23.
Manca.
,
O.
, and
Naso
,
V.
, 1990, “
Experimental Analysis of Natural Convection and Thermal Radiation in Vertical Channels
,”
ASME HTD
,
145
, pp.
13
21
.
You do not currently have access to this content.