The paper reports a continuation of an experimental investigation of the effect of fin pitch on the heat transfer performance of horizontal, integral-fin tubes for condensation of steam at near-atmospheric pressure. The effects of “drainage strips” located along the lower edge of finned and plain tubes have been studied. These gave significant increases in the heat transfer coefficient for finned tubes but had only marginal effect for the plain tube. Condensate retention angles have also been measured for simulated condensation using water, ethylene glycol, and refrigerant-113 for finned tubes with and without drainage strips. In the latter case the data agreed satisfactorily with theory. Drainage strips were found to reduce the extent of holdup significantly.
Skip Nav Destination
Article navigation
Research Papers
Horizontal Plain and Low-Finned Condenser Tubes—Effect of Fin Spacing and Drainage Strips on Heat Transfer and Condensate Retention
K. K. Yau,
K. K. Yau
University of Cambridge, United Kingdom
Search for other works by this author on:
J. R. Cooper,
J. R. Cooper
Department of Mechanical Engineering, Queen Mary College, University of London, United Kingdom
Search for other works by this author on:
J. W. Rose
J. W. Rose
Department of Mechanical Engineering, Queen Mary College, University of London, United Kingdom
Search for other works by this author on:
K. K. Yau
University of Cambridge, United Kingdom
J. R. Cooper
Department of Mechanical Engineering, Queen Mary College, University of London, United Kingdom
J. W. Rose
Department of Mechanical Engineering, Queen Mary College, University of London, United Kingdom
J. Heat Transfer. Nov 1986, 108(4): 946-950 (5 pages)
Published Online: November 1, 1986
Article history
Received:
August 23, 1985
Online:
October 20, 2009
Citation
Yau, K. K., Cooper, J. R., and Rose, J. W. (November 1, 1986). "Horizontal Plain and Low-Finned Condenser Tubes—Effect of Fin Spacing and Drainage Strips on Heat Transfer and Condensate Retention." ASME. J. Heat Transfer. November 1986; 108(4): 946–950. https://doi.org/10.1115/1.3247039
Download citation file:
Get Email Alerts
Cited By
Thermal Anisotropy and Heat Flux Deviation Degree of Composites
J. Heat Mass Transfer (May 2025)
Associate Editor's Recognition
J. Heat Mass Transfer (May 2025)
Related Articles
The Condensation of Ammonia-Water Mixtures in a Horizontal Shell and
Tube Condenser
J. Heat Transfer (August,2004)
Condensing Heat Transfer Enhancement on Vertical Spiral Double Fin Tubes With Drainage Gutters
J. Sol. Energy Eng (August,1985)
Measurement of Condensation Heat Transfer Coefficients at Near-Critical Pressures in Refrigerant Blends
J. Heat Transfer (August,2007)
Film Condensation of R-134a on Tube Arrays With Plain and Enhanced Surfaces: Part I—Experimental Heat Transfer Coefficients
J. Heat Transfer (January,2006)
Related Proceedings Papers
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Conditions That Can Make an A/C System Unacceptable
Heat Exchanger Engineering Techniques