Experiments were performed to determine the response of the heat transfer from a longitudinal fin array to the presence of clearance between the fin tips and an adjacent shroud. During the course of the experiments, the clearance was varied parametrically, starting with the no-clearance case; parametric variations of the fin height and of the rate of fluid flow through the array were also carried out. Air was the working fluid, and the flow was turbulent. The fully developed heat transfer coefficients corresponding to the presence and to the absence of clearance were compared under the condition of equal air flowrate, and substantial clearance-related reductions were found to exist. For clearances equal to 10, 20, and 30 percent of the fin height, the heat transfer coefficients were 85, 74, and 64 percent of those for the no-clearance case. The ratio of the with-clearance and no-clearance heat transfer coefficients was a function only of the clearance-to-fin-height ratio, independent of the air flowrate, the fin height, and the fin efficiency model used to evaluate the heat transfer coefficients. The presence of clearance slowed the rate of thermal development in the entrance region.
Skip Nav Destination
Article navigation
Research Papers
Effect of Tip-to-Shroud Clearance on Turbulent Heat Transfer From a Shrouded, Longitudinal Fin Array
E. M. Sparrow,
E. M. Sparrow
Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455
Search for other works by this author on:
D. S. Kadle
D. S. Kadle
Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455
Search for other works by this author on:
E. M. Sparrow
Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455
D. S. Kadle
Department of Mechanical Engineering, University of Minnesota, Minneapolis, MN 55455
J. Heat Transfer. Aug 1986, 108(3): 519-524 (6 pages)
Published Online: August 1, 1986
Article history
Received:
October 8, 1985
Online:
October 20, 2009
Citation
Sparrow, E. M., and Kadle, D. S. (August 1, 1986). "Effect of Tip-to-Shroud Clearance on Turbulent Heat Transfer From a Shrouded, Longitudinal Fin Array." ASME. J. Heat Transfer. August 1986; 108(3): 519–524. https://doi.org/10.1115/1.3246965
Download citation file:
Get Email Alerts
Cited By
Annulus-side flow boiling and visualization of a three-dimensionally enhanced tube
J. Heat Mass Transfer
Related Articles
Heat Transfer Downstream of a Fluid Withdrawal Branch in a Tube
J. Heat Transfer (February,1979)
Turbulent Heat Transfer Downstream of an Unsymmetric Blockage in a Tube
J. Heat Transfer (November,1978)
Periodically Converging-Diverging Tubes and Their Turbulent Heat Transfer, Pressure Drop, Fluid Flow, and Enhancement Characteristics
J. Heat Transfer (February,1984)
Turbulent Heat Transfer and Fluid Flow in an Unsymmetrically Heated Triangular Duct
J. Heat Transfer (November,1980)
Related Proceedings Papers
Related Chapters
Hydrodynamic Mass, Natural Frequencies and Mode Shapes
Flow-Induced Vibration Handbook for Nuclear and Process Equipment
Turbulent Fluid Flow and Heat Transfer
Applications of Mathematical Heat Transfer and Fluid Flow Models in Engineering and Medicine
Extended Surfaces
Thermal Management of Microelectronic Equipment