Methods for correcting data from gas turbine acceptance testing are discussed, focusing on matters which are not sufficiently covered by existing standards. First a brief outline is presented of the reasoning on which correction curves are based. Typical performance correction curves are shown together with the method of calculating mass flow rate and turbine inlet temperature from test data. A procedure for verifying guarantee data at a specific operating point is then given. Operation with water injection is then considered. Ways of correcting performance data are proposed, and the reasoning of following such a procedure is discussed. Corrections for water amount as well as power and efficiency are discussed. Data from actual gas turbine testing are used to demonstrate how the proposed procedure can be applied in actual cases of acceptance testing.
Skip Nav Destination
Article navigation
April 2004
Technical Papers
Gas Turbine Test Parameters Corrections Including Operation With Water Injection
K. Mathioudakis, Associate Professor
K. Mathioudakis, Associate Professor
Laboratory of Thermal Turbomachines, National Technical University of Athens, P.O. Box 64069, Athens 15710, Greece
Search for other works by this author on:
K. Mathioudakis, Associate Professor
Laboratory of Thermal Turbomachines, National Technical University of Athens, P.O. Box 64069, Athens 15710, Greece
Contributed by the International Gas Turbine Institute (IGTI) of THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS for publication in the ASME JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER. Paper presented at the International Gas Turbine and Aeroengine Congress and Exhibition, Amsterdam, The Netherlands, June 3–6, 2002; Paper No. 2002-GT-30466. Manuscript received by IGTI, December 2001, final revision, March 2002. Associate Editor: E. Benvenuti.
J. Eng. Gas Turbines Power. Apr 2004, 126(2): 334-341 (8 pages)
Published Online: June 7, 2004
Article history
Received:
December 1, 2001
Revised:
March 1, 2002
Online:
June 7, 2004
Citation
Mathioudakis, K. (June 7, 2004). "Gas Turbine Test Parameters Corrections Including Operation With Water Injection ." ASME. J. Eng. Gas Turbines Power. April 2004; 126(2): 334–341. https://doi.org/10.1115/1.1691443
Download citation file:
Get Email Alerts
Cited By
Temperature Dependence of Aerated Turbine Lubricating Oil Degradation from a Lab-Scale Test Rig
J. Eng. Gas Turbines Power
Multi-Disciplinary Surrogate-Based Optimization of a Compressor Rotor Blade Considering Ice Impact
J. Eng. Gas Turbines Power
Experimental Investigations on Carbon Segmented Seals With Smooth and Pocketed Pads
J. Eng. Gas Turbines Power
Related Articles
Analysis of the Effects of Water Injection on the Performance of a Gas Turbine
J. Eng. Gas Turbines Power (July,2002)
The Effect of Water Injection on Multispool Gas Turbine
Behavior
J. Eng. Gas Turbines Power (January,2006)
Data Reconciliation and Suspect Measurement Identification for Gas Turbine Cogeneration Systems
J. Eng. Gas Turbines Power (September,2013)
Application of a Computational Code to Simulate Interstage Injection Effects on GE Frame 7EA Gas Turbine
J. Eng. Gas Turbines Power (January,2008)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Introduction
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Control and Operational Performance
Closed-Cycle Gas Turbines: Operating Experience and Future Potential