A new tendon transfer technique is proposed for the reconstruction of the paralyzed shoulders secondary to Brachial Plexus Injury (BPI). In this tendon transfer, the long head of the biceps tendons is utilized as a bridging tendon graft. It is reflected at the exit of the bicipital groove, passed through the deltoid and directed to the trapezius. The technique is referred to here as the Reflected Long Head Bicepts (RLHB) technique. This study evaluated the effect of this tendon transfer on the anterior, posterior, and inferior stability of the reconstructed should using cadaveric specimens. It was shown that loading of the RLHB contributed significantly to anterior stability of the reconstructed shoulder for 90 deg elevation in the scapula plane. The mean displacement was reduced by 56 percent with RLHB loaded (p<0.01), by 56 percent with the rotator cuff loaded (p<0.005), and by 67 percent with both the RLHB and the rotator cuff loaded (p<0.004). For the post-operation conditions, variation of the directions of RLHB had no significant effect on joint displacement in response to anterior loading. The RLHB tendon also contributed to the posterior and inferior stability for the low and middle elevations in the plane of scapula. Two variations of the RLHB tendon transfer procedures, namely the “Sub-Deltoid” and the “Through-Deltoid” techniques, were introduced and studied. These two techniques did not seem to have significantly different effects on the displacement of the humeral head in response to both posterior and inferior loading. The results of this study seemed to support the clinical feasibility of this tendon transfer approach as far as the biomedical stability of the reconstruction is concerned.
Skip Nav Destination
Article navigation
June 2001
Technical Papers
Stability of Reconstructed Paralyzed Shoulders Using a Reflected Long Head Biceps Technique
C. Y. Tang,
C. Y. Tang
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Kowloon, Hong Kong
Search for other works by this author on:
A. F. T. Mak,
A. F. T. Mak
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Kowloon, Hong Kong
Search for other works by this author on:
L. K. Hung,
L. K. Hung
Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
Search for other works by this author on:
H. S. Wong,
H. S. Wong
Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
Search for other works by this author on:
T. Pacaldo
T. Pacaldo
Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
Search for other works by this author on:
C. Y. Tang
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Kowloon, Hong Kong
A. F. T. Mak
Jockey Club Rehabilitation Engineering Center, The Hong Kong Polytechnic University, Kowloon, Hong Kong
L. K. Hung
Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
H. S. Wong
Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
T. Pacaldo
Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
Contributed by the Bioengineering Division for publication in the JOURNAL OF BIOMECHANICAL ENGINEERING. Manuscript received by the Bioengineering Division August 31, 1999; revised manuscript received January 11, 2001. Associate Editor: K.-N. An.
J Biomech Eng. Jun 2001, 123(3): 227-233 (7 pages)
Published Online: August 31, 1999
Article history
Received:
August 31, 1999
Received:
January 11, 2001
Citation
Tang , C. Y., Mak, A. F. T., Hung , L. K., Wong , H. S., and Pacaldo, T. (August 31, 1999). "Stability of Reconstructed Paralyzed Shoulders Using a Reflected Long Head Biceps Technique ." ASME. J Biomech Eng. June 2001; 123(3): 227–233. https://doi.org/10.1115/1.1372700
Download citation file:
Get Email Alerts
Cited By
Related Articles
Design of an Endoreactor for the Cultivation of a Joint-Like-Structure
J. Med. Devices (June,2009)
A Biomechanical Model of the Foot: The Role of Muscles, Tendons, and Ligaments
J Biomech Eng (June,2002)
Design of a Compliant Steerable Arthroscopic Punch
J. Med. Devices (June,2010)
Application of a Three-Dimensional Computational Wrist Model to Proximal Row Carpectomy
J Biomech Eng (June,2015)
Related Proceedings Papers
Related Chapters
Tendon End Anchor Testing
Commentary on Articles CC-2000, CC-3000 and CC-4000
Appendix F—Tendon End Anchor Testing
Commentary on Article CC-3000 Design
IWE and IWL
Online Companion Guide to the ASME Boiler & Pressure Vessel Codes