The hypothesis is made that a disturbance in blood flow at one place can be detected in the arterial pulse waves at a distant site. This hypothesis was motivated by the traditional Chinese medicine which uses arterial pulse waves as a principal means of diagnosis. We formulated a test by asking whether a disturbance to the blood flow in a leg can be detected by changes in the pulse waves in the radial arteries. In particular, we ask whether the radial artery can differentiate a disturbance in the right leg from that in the left leg. We put force transducers on the radial arteries, depressed them by a specific amount, and recorded the force waves in response to a 2-min occlusion of the blood flow in the right or left tibial artery. The results show that the radial artery force waves do change in response to the flow disturbance. For a given individual, the force varies with the location of the force transducer on the radial artery, the specific amount of initial depression, and the right or left leg occlusion. Generally, an occlusion in the right leg reduces the force level in both radial arteries, the more so in the right radial artery than in the left. Although the discrimination is not very strong, the phenomenon is novel, and warrants further investigation.
Skip Nav Destination
Article navigation
August 1985
Research Papers
On the Detection of Messages Carried in Arterial Pulse Waves
K. Dai,
K. Dai
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093
Search for other works by this author on:
H. Xue,
H. Xue
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093; and Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
Search for other works by this author on:
R. Dou,
R. Dou
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093
Search for other works by this author on:
Y. C. Fung
Y. C. Fung
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093
Search for other works by this author on:
K. Dai
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093
H. Xue
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093; and Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
R. Dou
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093
Y. C. Fung
Department of AMES/Bioengineering, University of California, San Diego, La Jolla, Calif. 92093
J Biomech Eng. Aug 1985, 107(3): 268-273 (6 pages)
Published Online: August 1, 1985
Article history
Received:
March 25, 1985
Online:
June 15, 2009
Article
Article discussed|
View article
Connected Content
Citation
Dai, K., Xue, H., Dou, R., and Fung, Y. C. (August 1, 1985). "On the Detection of Messages Carried in Arterial Pulse Waves." ASME. J Biomech Eng. August 1985; 107(3): 268–273. https://doi.org/10.1115/1.3138552
Download citation file:
Get Email Alerts
Cited By
Related Articles
Persistence of Asymmetry in Nonaxisymmetric Entry Flow in a Circular Cylindrical Tube and Its Relevance to Arterial Pulse Wave Diagnosis
J Biomech Eng (February,1989)
A Novel Transducer for Measurement of Skin Blood Flow Using Radio Frequency Energy
ASME J of Medical Diagnostics (November,2019)
Assessment of Energy Requirement for the Retinal Arterial Network in Normal and Hypertensive Subjects
J Biomech Eng (January,2012)
Related Proceedings Papers
Related Chapters
Introduction and Scope
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Wavelet Analysis of Biomedical Time Series for Characterization of Blood Circulation Patterns and Human Health Status
Intelligent Engineering Systems through Artificial Neural Networks, Volume 16
Appendix: Non-Biomedical Application
Modified Detrended Fluctuation Analysis (mDFA)