In cancer hyperthermia treatments, it is important to be able to predict complete tissue temperature fields from sampled temperatures taken at the limited number of locations allowed by clinical constraints. An initial attempt to do this automatically using unconstrained optimization techniques to minimize the differences between experimental temperatures and temperatures predicted from treatment simulations has been previously reported [1]. This paper reports on a comparative study which applies a range of different optimization techniques (relaxation, steepest descent, conjugate gradient, Gauss, Box-Kanemasu, and Modified Box-Kanemasu) to this problem. The results show that the Gauss method converges more rapidly than the others, and that it converges to the correct solution regardless of the initial guess for the unknown blood perfusion vector. A sensitivity study of the error space is also performed, and the relationships between the error space characteristics and the comparative speeds of the optimization techniques are discussed.
Skip Nav Destination
Article navigation
August 1985
Research Papers
A Comparative Evaluation of Unconstrained Optimization Methods Applied to the Thermal Tomography Problem
S. T. Clegg,
S. T. Clegg
Aerospace and Mechanical Engineering Department, University of Arizona, Tucson, Ariz. 85721
Search for other works by this author on:
R. B. Roemer
R. B. Roemer
Radiation Oncology Division, Arizona Health Sciences Center, Tucson, Ariz. 85724
Search for other works by this author on:
S. T. Clegg
Aerospace and Mechanical Engineering Department, University of Arizona, Tucson, Ariz. 85721
R. B. Roemer
Radiation Oncology Division, Arizona Health Sciences Center, Tucson, Ariz. 85724
J Biomech Eng. Aug 1985, 107(3): 228-233 (6 pages)
Published Online: August 1, 1985
Article history
Received:
August 1, 1983
Revised:
April 29, 1985
Online:
June 15, 2009
Citation
Clegg, S. T., and Roemer, R. B. (August 1, 1985). "A Comparative Evaluation of Unconstrained Optimization Methods Applied to the Thermal Tomography Problem." ASME. J Biomech Eng. August 1985; 107(3): 228–233. https://doi.org/10.1115/1.3138547
Download citation file:
Get Email Alerts
Related Articles
Pre-Clinical Evaluation of Direct Current Ablation for the Treatment of Benign Prostatic Hyperplasia
J. Med. Devices (June,2009)
Intra-Operative Pulse Oximetry
J. Med. Devices (June,2009)
Advances in Finite Element Simulations of Elastosonography for Breast Lesion Detection
J Biomech Eng (August,2011)
Numerical Simulation for Heat Transfer in Prostate Cancer Cryosurgery
J Biomech Eng (April,2005)
Related Proceedings Papers
Related Chapters
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Experimental Studies
Nanoparticles and Brain Tumor Treatment
Conclusion & executive summary
Photodynamic Therapy Mediated by Fullerenes and their Derivatives