The purpose of this study was to measure stresses associated with turbulence (Reynolds stresses), in the region of a 29-mm-dia porcine bioprosthetic valve (Hancock, Model 242). Studies were performed in an in vitro pulse duplicating system with the valve mounted in the aortic position. The Reynolds stresses were calculated from velocities obtained with a two channel laser Doppler anemometer. The largest Reynolds shear stress and normal stress occurred at the highest stroke volume used (80 mL). Averaged over ejection they were 38 dynes/cm2 and 380 dynes/cm2, respectively. The maximal instantaneous Reynolds shear stress was 2500 dynes/cm2 and the maximal instantaneous Reynolds normal stress was 6800 dynes/cm2. Stresses of these magnitudes are in the range reported to damage platelets.
Skip Nav Destination
Article navigation
August 1985
Research Papers
Turbulent Stresses in the Region of a Hancock Porcine Bioprosthetic Aortic Valve
F. J. Walburn,
F. J. Walburn
Research Division, Miami Heart Institute, Miami Beach, Fla. 33140
Search for other works by this author on:
H. N. Sabbah,
H. N. Sabbah
Department of Medicine (Division of Cardiovascular Medicine), and Department of Surgery, Henry Ford Hospital, Detroit, Mich. 48202
Search for other works by this author on:
P. D. Stein
P. D. Stein
Department of Medicine (Division of Cardiovascular Medicine), and Department of Surgery, Henry Ford Hospital, Detroit, Mich. 48202
Search for other works by this author on:
F. J. Walburn
Research Division, Miami Heart Institute, Miami Beach, Fla. 33140
H. N. Sabbah
Department of Medicine (Division of Cardiovascular Medicine), and Department of Surgery, Henry Ford Hospital, Detroit, Mich. 48202
P. D. Stein
Department of Medicine (Division of Cardiovascular Medicine), and Department of Surgery, Henry Ford Hospital, Detroit, Mich. 48202
J Biomech Eng. Aug 1985, 107(3): 200-205 (6 pages)
Published Online: August 1, 1985
Article history
Received:
June 7, 1983
Revised:
March 18, 1985
Online:
June 15, 2009
Citation
Walburn, F. J., Sabbah, H. N., and Stein, P. D. (August 1, 1985). "Turbulent Stresses in the Region of a Hancock Porcine Bioprosthetic Aortic Valve." ASME. J Biomech Eng. August 1985; 107(3): 200–205. https://doi.org/10.1115/1.3138544
Download citation file:
Get Email Alerts
Cited By
Related Articles
Two-Component Laser Velocimeter Measurements Downstream of Heart Valve Prostheses in Pulsatile Flow
J Biomech Eng (February,1986)
Turbulent Stresses in the Region of Aortic and Pulmonary Valves
J Biomech Eng (August,1982)
Design of a Pulsatile Flow Facility to Evaluate Thrombogenic Potential of Implantable Cardiac Devices
J Biomech Eng (April,2015)
Vortex Shedding as a Mechanism for Free Emboli Formation in Mechanical Heart Valves
J Biomech Eng (April,2000)
Related Proceedings Papers
Related Chapters
Introduction
Mechanical Blood Trauma in Circulatory-Assist Devices
Concluding remarks
Mechanical Blood Trauma in Circulatory-Assist Devices
Glass Laser Materials Testing at Naval Research Laboratory
Damage in Laser Glass